Something specific, usually: a fan quietly failing, a sump lid left unsealed after pump service, a membrane seam letting go, or a renovation that opened new pathways. The gauge plus a process of elimination finds it.
More detail
Start at the manometer and let it split the problem. Columns at or near level: the fan is the story, check the breaker, then book the swap. Columns holding their startup mark: the fan is fine and the pathway picture changed, so think about what happened since the last good test. A plumber in the sump? Reseal the lid. Basement finished, bathroom roughed in, slab cut for plumbing? New openings need sealing, and the suction field may need re-evaluating. Crawl membrane? Walk it for seam separations and boot failures. Also audit the test itself before anything else: open windows, an evaporative cooler running, or a device parked next to a drafty walkout door will manufacture a scare. A mitigated house that genuinely drifted up gets a service visit, a targeted fix, and a retest, usually all within the repair price band. See system repair and reading the manometer.