What is the U-shaped gauge on my radon pipe telling me?

Direct answer

Whether the fan is pulling. The two liquid columns sit at different heights while the system holds suction; the installer marks the startup reading. Columns drifting back toward level mean lost suction, and dead level means the fan has stopped.

More detail

The manometer is the only instrument most owners will ever read on their system, and it repays thirty seconds a month. Compare the liquid against the startup mark. Same offset: all is well. Noticeably shallower offset: suction is bleeding somewhere, a tired fan, a new crack, an unsealed sump lid after pump service, or a membrane seam letting go in the crawl. Level liquid: the fan is off, so check the breaker and the switch (systems should be wired to circuits nobody idly switches, but renovations create surprises), then call for a repair. One subtlety: a much deeper offset than startup is also worth a call, since it can mean the suction field has clogged or iced and the fan is straining against a blockage. The gauge proves airflow, never air quality, so the two-year retest stays on the calendar regardless. The repair service handles fans, gauges, and seals.

Authoritative sources

Ready to get started?

About half of Fort Collins homes test at or above the EPA action level, and Larimer County averages six times the national figure. Mon-Sat 8am-6pm.

Call (970) 426-0858Text us